FAQ
We are Manufacturer, Supplier, Exporter of Wired Nurse Call Systems, IP Based Software, Data Analysis Software, Wireless Bed Unit With Handset, OPD Call Systems from Pune, Maharashtra, India.
- 1. What type of Cabling is used?
- It requires good Quality CAT 5 Cable.
- 2. How the Cabling is done?
- Cabling is very simple to do. Please contact us to get cabling diagram.
- 3. How the connections are done?
- Connections are very easy & with the basic Electrical knowledge one can do the connections.
- 4. Is the system reliable?
- Yes the system is reliable & time tasted.
- 5. Does it require any periodic Maintenance?
- As this is Electronic system & does not consist of any moving part virtually there is no maintenance of the system. The System is design to work 24 hrs & 365 days continually.
-
1. What is the Range of the System (What is the longest distance it can receive the Signal form)?
- 100 meters in open air. With obstacles & door closed it can work smoothly upto 60-70 meters.
-
2. What if the distance is more than 60-70 meters with obstacles?
- We have signal repeaters (Boosters) which can be put in between main Control unit & the Call Unit. The signal repeaters increase the signal strength so the call unit which is at higher distance can work with control unit.
- 3. On one Wireless Control Unit maximum how many Call Units can work?
- On a single system max 30 Call Units can work.
- 4. What if at a place more than two control units are there? Will both the controls units receive signal from Call Unit? i.e. Will cross connection take place?
- No. Infact At a single/same place we can have 64 Control Units & still there will not be any cross connection.
- 5. What is the frequency it uses?
- It uses 433 Mhz frequency range.
- 6. Does wireless system disturb other medical device functions?
- No
- 7. How the setting is done in Wireless System?
- Setting is very simple & you can start using the system immediately.
-
1. At Nurse Station
- 1. One 230 V 5 Amp regular Power Point is needed to supply the power to the system.
-
2. One rack/stand for control unit ( Size Of the Control Unit Box is 315 mm Length x 225 mm Width x 60 mm Height) One can hide the Control Unit Box if they wish & just hang the Display Unit On wall.
- 3. To hide the cable of Display Unit we advice to put plastic conduct pipe in the wall from Control Unit to the display unit.
- 2. At the Patient End or in The patient Room.
- 1. 2 Module Electrical Metal Box ( In case of Under Wall Wiring) or 2 Module Electrical Surface box ( In case of Open Wiring) for Door Indicator, Bed Unit & Toilet Unit one each.
-
1. At Nurse Station
- 1.One 230 V 5 Amp regular Power Point is needed to supply the power to the system.
-
2. At the Patient End or in The patient Room.
- 1. Two (2) Module Electrical Metal Box ( In case of Under Wall Wiring) or 2 Module Electrical Surface box ( In case of Open Wiring) for Bed Unit & Toilet Unit one each.